Termostat BTC71

438,88 Lei cu TVA inclus

     

BTC7100-4110000          (c-da releu)         72x72x60mm
BTC8100-4110000         
 (contact releu)   48x96x65  sau 72x72x65
Regulator temperatura multi-input ( K, J, E, T, L, N, B, S, R, Pt100DIN, Pt100JIS), dublu display, 4 digiti, tensiune alimentare 90-250VAC, cu iesire comutator releu sau SSR (c-da releu static), rampa crestere sau descrestere temperatura setabila (multiple functii alarma, inclusiv timer), varianta standard fara alarma

 
Optional se mai poate instala pe acest aparat
 
1.      Alarma contact releu………………………………………………………………......10,00 Euro
2.      Ieşirea 2 de c-da (out 2), contact releu………………………………………………...12,00 Euro
3.      Ieşire 1 sau 2 în semnal unificat, 0/4-20mA, 0-10V, 1-5V, 0-5V, izolata galvanic…..26,00 Euro
4.      Seriala RS-485 sau RS-232, izolata galvanic.……………………………………… .35,00 Euro
5.      Retransmisie semnal unificat 0-10VDC, 0/4-20mA.....................................................38,00 Euro
6.      Sursa 20VDC/25mA sau 12VDC/40mA sau 5VDC/80mA, izolata galvanic……….   26,00 Euro
7.      Convertor RS485-RS232, izolat galvanic intrare-ieşire, tip SNA-10A (permite conectarea în paralel a 247 buc.regulatoare BRAINCHILD, indiferent de tip, cu seriala RS485)....................68,00 Euro
8. Software Comunicator (Valabil pentru PC-comunicaţie seriala cu regulatoare)............170,00 Euro

 

Features:

The Fuzzy Logic plus PID microprocessor-based profiling controller with many segments of ramp and dwell, incorporate two bright, easy to read 4-digit LED displays, indicating process value and set point value. The Fuzzy Logic technology enables a process to reach a predetermined set point in the shortest time, with the minimum of overshoot during power-up or external load disturbance.

As a professional and experienced manufacturer, we supply high-performance and quality ramp soak controllers, which is also called programmable temperature controllers.

FEATURES

  • Total 9 profiles, a profile with 16, 32 or 64 segments at most
  • Each segment to be configured as a ramp or dwell(soak)
  • Fast A-D sampling rate (5 times/s)
  • After an event the process goes to run, hold, abort, manual, failure transfer, off mode, next segment or select the second PID values
  • High accuracy of 18-bit A to D input, and 15-bit D to A output
  • The fast sample rate of 200 msec
  • Fuzzy control to reach set point at the least overshooting ans less time
  • Up to three relays are configurable for event output
  • Analog retransmission of process value & set point value
  • Optional RS-485 or 232 communications
  • Programmable port for easy configuration or calibration
  • Lockout protection for security requirement
  • Bumpless transfer of safely control while sensor breaks
  • Digital filter to improve the stability of process value
  • SEL function for easy operation
 

 


 

 


 

Specification:

Power
90 - 250 VAC, 47 - 63 Hz, 12VA, 5W maximum
11 - 26 VAC / VDC, SELV, Limited Energy, 12VA, 5W maximum

 

Signal Input
Resolution : 18 bits
Sampling Rate : 5 times / second
Maximum Rating : -2 VDC minimum, 12 VDC maximum( 1 minute for mA input )
Temperature Effect : ±1.5 uV/ °C for all inputs except mA input
                               ±3.0 uV/ °C for mA input
Sensor Lead Resistance Effect :
   T/C: 0.2uV/ohm
   3-wire RTD: 2.6 °C/ohm of resistance difference of two leads
   2-wire RTD: 2.6 °C/ohm of resistance sum of two leads
Burn-out Current : 200nA
Common Mode Rejection Ratio ( CMRR ) : 120dB
Normal Mode Rejection Ratio ( NMRR ) : 55dB
Sensor Break Detection :
   Sensor open for TC, RTD and mV inputs,
   Sensor short for RTD input,
   below 1 mA for 4-20 mA input,
   below 0.25V for 1 - 5 V input, unavailable for other inputs.
Sensor Break Responding Time :
   Within 4 seconds for TC, RTD and mV inputs,
   0.1 second for 4-20 mA and 1 - 5 V inputs.

 

Characteristics :

 

Type
Range
Accuracy@ 25 °C
Input Impedance
J

-120 ~ 1000 °C
(-184 ~ 1832 °F)

±2 °C
2.2MΩ
K
-200 ~ 1370 °C
(-328 ~ 2498°F)
±2 °C
2.2MΩ
T
-250 ~ 400°C
(-418 ~ 752°F)
±2 °C
2.2MΩ
E
-100 ~ 900 °C
(-148 ~ 1652 °F)
±2 °C
2.2MΩ
B
0 ~ 1800 °C
(32 ~ 3272 °F)
±2 °C
(200°C - 1800°C)
2.2MΩ
R
0 ~ 1767.8 °C
(32 ~ 3214 °F)
±2 °C
2.2MΩ
S
0 ~ 1767.8 °C
(32 ~ 3214 °F)
±2 °C
2.2MΩ
N
-250 ~ 1300 °C
(-418 ~ 2372 °F)
±2 °C
2.2MΩ
L
-200 ~ 900 °C
(-328 ~ 1652 °F)
±2 °C
2.2MΩ
PT100
(DIN)
-210 ~ 700 °C
(-346 ~ 1292 °F)
±0.4°C
1.3KΩ
PT100
(JIS)
-200 ~ 600 °C
(-328 ~ 1112 °F)
±0.4°C
1.3KΩ
mV
-8 ~ 70mV
±0.05%
2.2MΩ
mA
-3 ~ 27mA
±0.05%
70.5Ω
V
-1.3 ~ 11.5V
±0.05%
650KΩ

 

Output 1 / Output 2
Relay Rating : 2A/240 VAC, life cycles 200,000 for resistive load
Pulsed Voltage : Source Voltage 5V, current limiting resistance 66Ω .
Linear Output Characteristics:
Type
Zero Tolerance
Span Tolerance
Load Capacity
4-20 mA

3.6-4 mA

20-21 mA
500Ω max.
0-20 mA
0 mA
20-21 mA
500Ω max.
0-5 V

0 V

5-5.25 V
10KΩ min.
1-5 V
0.9-1 V
5-5.25 V
10KΩ min.
0-10 V
0 V
10-10.5 V
10KΩ min.

 

Linear Output
   Resolution : 15 bits
   Output Regulation : 0.02 % for full load change
   Output Settling Time : 0.1 sec. ( stable to 99.9 % )
   Isolation Breakdown Voltage : 1000 VAC
   Temperature Effect : ±0.01 % of SPAN / °C

 

Triac ( SSR ) Output
   Rating : 1A / 240 VAC
   Inrush Current : 20A for 1 cycle
   Min. Load Current : 50 mA rms
   Max. Off-state Leakage : 3 mA rms
   Max. On-state Voltage : 1.5 V rms
   Insulation Resistance : 1000 Mohms min. at 500 VDC
   Dielectric Strength : 2500 VAC for 1 minute

 

DC Voltage Supply characteristics(Install at Output2)
Type
Tolerance
Max. Output Current
Ripple Voltage
Isolation Brrifer
20V

±1V

25mA
0.2Vp-p
500VAC
12V
±0.6V
40mA
0.1Vp-p
500VAC
5V
±0.25V
80mA
0.05Vp-p
500VAC
Alarm
Alarm Relay :Form C,Max. rating 2A/240VAC, life cycles 200,000 for resistive load.
Alarm Functions : Dwell timer,
                            Deviation High / Low Alarm,
                            Deviation Band High / Low Alarm
                            PV High / Low Alarm
Alarm Mode : Normal, Latching, Hold, Latching / Hold.
Dwell Timer : 0.1 - 4553.6 minutes

 

Data Communication
Interface : RS-232 ( 1 unit ), RS-485 ( up to 247 units )
Protocol : Modbus Protocol RTU mode
Address : 1 - 247
Baud Rate : 2.4 ~ 38.4 Kbits/sec
Parity Bit : None, Even or Odd
Stop Bit : 1 or 2 bits
Communication Buffer : 64 bytes

 

Analog Retransmission
Output Signal : 4-20 mA, 0-20 mA, 0-1V, 0-5V, 1-5V, 0-10V
Resolution : 15 bits
Accuracy : ±0.05 % of span ±0.0025 %/ °C
Load Resistance : 0 - 500 ohms ( for current output ),10 K ohm minimum ( for voltage output )
Output Regulation : 0.01 % for full load change
Output Settling Time : 0.1 sec. (stable to 99.9 % )
Isolation Breakdown Voltage : 1000 VAC min.
Integral Linearity Error : ±0.005 % of span
Temperature Effect : ±0.0025 % of span/ °C
Saturation Low : 0 mA ( or 0V )
Saturation High : 22.2 mA ( or 5.55V, 11.1V min. )
Linear Output Range : 0 - 22.2mA(0-20mA or 4-20mA),
                                 0 - 5.55V ( 0 - 5V, 1 - 5V ),
                                 0 - 11.1 V ( 0 - 10V )

 

User Interface
Dual 4-digit LED Displays
Keypad : 4 keys
Programming Port : For automatic setup, calibration and testing
Communication Port : RS-232 and RS-485

 

Control Mode
Output 1 : Reverse ( heating ) or direct ( cooling )action
Output 2 : PID cooling control, cooling P band 50 ~ 300% of PB, dead band -36.0 ~ 36.0% of PB
ON-OFF : 0.1 - 90.0 ( °F ) hysteresis control ( P band = 0 )
P or PD : 0 - 100.0 % offset adjustment
PID : Fuzzy logic modified , Proportional band 0.1 ~ 900.0°F ,
Integral time 0 - 1000 seconds , Derivative time 0 - 360.0 seconds
Cycle Time : 0.1 - 90.0 seconds
Manual Control : Heat (MV1) and Cool (MV2)
Auto-tuning : Cold start and warm start
Failure Mode : Auto-transfer to manual mode while sensor break or A-D converter damage
Ramping Control : 0 ~ 900.0°F/minute or 0 ~ 900.0 °F/hour ramp rate

 

Digital Filter
Function : First order
Time Constant : 0, 0.2, 0.5, 1, 2, 5, 10, 20, 30, 60 seconds programmable

 

Profiler
Number of profiles : 9
Number of Segment per profile
     Profile 1,2,3,4 : 16
     Profile 5,6,7 : 32
     Profile 8,9 : 64
Event Outputs : 3

 

Environmental & Physical
Operating Temperature : -10°C to 50°C
Storage Temperature : -40°C to 60°C
Humidity : 0 to 90 % RH ( non-condensing )
Altitude : 2000m maximum
Pollution : Degree 2
Insulation Resistance : 20 Mohms min. ( at 500 VDC )
Dielectric Strength : 2000 VAC, 50/60 Hz for 1 minute
Vibration Resistance : 10 - 55 Hz, 10 m/s² for 2 hours
Shock Resistance : 200 m/s² ( 20 g )
Moldings : Flame retardant polycarbonate
Dimensions :
P41 ---96mm(W) X 96mm(H) X 65mm(D), 53 mm depth behind panel

 

P91 ---48mm(W) X 48mm(H) X 116mm(D), 105 mm depth behind panel

 

Weight :
P41 --- 250 grams
P91 --- 150 grams

 

Approval Standards
Safety : UL 61010C-1 , CSA C22.2 No. 24-93 , EN61010-1 (IEC1010-1)

 

Protective Class :
          IP65 front panel with additional option,
          IP50 front panel without additional option,
          all indoor use,
          IP 20 housing and terminals with protective cover.

 

EMC : EN61326

 


 

Other Description:

P41 - □□□□□□□□
              1      2      3      4      5      6      7      8     

 

1     Power Input
               4: 90 - 264 VAC, 47-63 HZ
               5: 11 - 26 VAC or VDC, SELV, Limited Energy

 

2     Signal Input
               1: Standard Input
                        Input 1-Universal Input
                                 Thermocouple: J, K, T, E, B, R, S, N, L, C, P
                                 RTD: PT100 DIN, PT100 JIS
                                 Voltage: Voltage: 0-60mV
               5: 0-10V, 0-1V, 0-5V, 1-5V
               6: 0-20/4-20 mA
               9: Special Order

 

3    Output 1
               0: None
               1: Relay rated 2A / 240VAC
               2: Pulsed voltage to drive SSR, 5V / 30mA
               3: Isolated 4 - 20mA / 0 - 20mA
               4: Isolated 1 - 5V / 0 - 5V / 0 - 10V
               6: Triac output 1A / 240VAC,SSR
               C: Pulsed Voltage to drive SSR, 14V/40mA
               9: Special order

 

4    Output 2
               0: None
               1: Relay rated 2A/240VAC
               2: Pulsed voltage to drive SSR, 5V / 30mA
               3: Isolated 4 - 20mA / 0 - 20mA
               4: Isolated 1 - 5V / 0 - 5V / 0 - 10V
               6: Triac output, 1A / 240VAC, SSR
               7: Isolated 20V / 25 mA DC Output Power Supply
               8: Isolated 12V / 40 mA DC Output Power Supply
               9: Isolated 5V / 80 mA DC Output Power Supply
               C: Pulsed Voltage to drive SSR, 14V/40mA
               A: Special order

 

5    Output 3
               0: None
               1: Relay rated 2A/240VAC
               2: Pulsed voltage to drive SSR, 5V/30mA
               6: Triac output 1A / 240VAC,SSR
               7: Isolated 20V/25mA transducer power supply
               8: Isolated 12V/40mA transducer power supply
               A: Isolated 5V/80mA transducer power supply
               C: Pulsed voltage to drive SSR, 14V/40mA
               9: Special order

 

6    Output 4
               0: None
               1: Relay rated 2A/240VAC
               2: Pulsed voltage to drive SSR, 5V/30mA
               3: Isolated 4 - 20mA / 0 - 20mA
               4: Isolated 1 - 5V / 0 - 5V/0 - 10V
               6: Triac output 1A / 240VAC,SSR
               7: Isolated 20V/25mA transducer power supply
               8: Isolated 12V/40mA transducer power supply
               A: Isolated 5V/80mA transducer power supply
               C: Pulsed voltage to drive SSR, 14V/40mA
               9: Special order

 

7    Output 5
               0: None
               3: Isolated 4 - 20mA / 0 - 20mA
               4: Isolated 1 - 5V / 0 - 5V/0 - 10V
               7: Isolated 20V/25mA transducer power supply
               8: Isolated 12V/40mA transducer power supply
               A: Isolated 5V/80mA transducer power supply
               D: Isolated RS-485 interface
               E: Isolated RS-232 interface

 

8    Options
               0: Panel mount IP50 standard
               1: Panel mount IP65 water resistant rubber installed
               2: DIN rail mount with IP50 (for P91 only)
               3: DIN rail mount with IP65 (for P91 only)

 

 




 

This is the detailed information for 96X96 mm Ramp soak controllers, P41. The information includes model, name, description and specification for 96X96 mm Ramp soak controllers, P41. Related Keywords : Ramp soak controllers



 


  • Model: BTC 71
  • Produs de: Brainchild


Copyright © 2019 Euroenerg. Powered by Euroenerg